Review



af2000 asymmetric flow field flow fractionation af4 module  (Postnova Analytics)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 86

    Structured Review

    Postnova Analytics af2000 asymmetric flow field flow fractionation af4 module
    <t>FI-AF4-MD</t> of Poly­(A) LNP formulations. MALS-90° elution profiles with FWHM-integrated radius of gyration and hydrodynamic radii for (A) A-LNPs, (B) B-LNPs, and (C) C-LNPs ( n = 3 ± SD). Cumulative distributions for (D) radius of gyration, (E) hydrodynamic radius, and (F) shape factor ( n = 3), with respective 10, 50, and 90 distributional values for (G) radius of gyration, (H) hydrodynamic radius, and (I) shape factor for A-LNPs, B-LNPs and C-LNPs ( n = 3 ± SD).
    Af2000 Asymmetric Flow Field Flow Fractionation Af4 Module, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/af2000 asymmetric flow field flow fractionation af4 module/product/Postnova Analytics
    Average 86 stars, based on 1 article reviews
    af2000 asymmetric flow field flow fractionation af4 module - by Bioz Stars, 2026-05
    86/100 stars

    Images

    1) Product Images from "The Use of Enhanced Analytical Pipelines for the Characterization of Poly(A) and Poly(A)-LNP Formulation Critical Quality Attributes"

    Article Title: The Use of Enhanced Analytical Pipelines for the Characterization of Poly(A) and Poly(A)-LNP Formulation Critical Quality Attributes

    Journal: Molecular Pharmaceutics

    doi: 10.1021/acs.molpharmaceut.5c00614

    FI-AF4-MD of Poly­(A) LNP formulations. MALS-90° elution profiles with FWHM-integrated radius of gyration and hydrodynamic radii for (A) A-LNPs, (B) B-LNPs, and (C) C-LNPs ( n = 3 ± SD). Cumulative distributions for (D) radius of gyration, (E) hydrodynamic radius, and (F) shape factor ( n = 3), with respective 10, 50, and 90 distributional values for (G) radius of gyration, (H) hydrodynamic radius, and (I) shape factor for A-LNPs, B-LNPs and C-LNPs ( n = 3 ± SD).
    Figure Legend Snippet: FI-AF4-MD of Poly­(A) LNP formulations. MALS-90° elution profiles with FWHM-integrated radius of gyration and hydrodynamic radii for (A) A-LNPs, (B) B-LNPs, and (C) C-LNPs ( n = 3 ± SD). Cumulative distributions for (D) radius of gyration, (E) hydrodynamic radius, and (F) shape factor ( n = 3), with respective 10, 50, and 90 distributional values for (G) radius of gyration, (H) hydrodynamic radius, and (I) shape factor for A-LNPs, B-LNPs and C-LNPs ( n = 3 ± SD).

    Techniques Used:



    Similar Products

    86
    Postnova Analytics af2000 asymmetric flow field flow fractionation af4 module
    <t>FI-AF4-MD</t> of Poly­(A) LNP formulations. MALS-90° elution profiles with FWHM-integrated radius of gyration and hydrodynamic radii for (A) A-LNPs, (B) B-LNPs, and (C) C-LNPs ( n = 3 ± SD). Cumulative distributions for (D) radius of gyration, (E) hydrodynamic radius, and (F) shape factor ( n = 3), with respective 10, 50, and 90 distributional values for (G) radius of gyration, (H) hydrodynamic radius, and (I) shape factor for A-LNPs, B-LNPs and C-LNPs ( n = 3 ± SD).
    Af2000 Asymmetric Flow Field Flow Fractionation Af4 Module, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/af2000 asymmetric flow field flow fractionation af4 module/product/Postnova Analytics
    Average 86 stars, based on 1 article reviews
    af2000 asymmetric flow field flow fractionation af4 module - by Bioz Stars, 2026-05
    86/100 stars
      Buy from Supplier

    86
    Postnova Analytics af2000 asymmetric flow field flow fractionation af4 system
    <t>FI-AF4-MD</t> of Poly­(A) LNP formulations. MALS-90° elution profiles with FWHM-integrated radius of gyration and hydrodynamic radii for (A) A-LNPs, (B) B-LNPs, and (C) C-LNPs ( n = 3 ± SD). Cumulative distributions for (D) radius of gyration, (E) hydrodynamic radius, and (F) shape factor ( n = 3), with respective 10, 50, and 90 distributional values for (G) radius of gyration, (H) hydrodynamic radius, and (I) shape factor for A-LNPs, B-LNPs and C-LNPs ( n = 3 ± SD).
    Af2000 Asymmetric Flow Field Flow Fractionation Af4 System, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/af2000 asymmetric flow field flow fractionation af4 system/product/Postnova Analytics
    Average 86 stars, based on 1 article reviews
    af2000 asymmetric flow field flow fractionation af4 system - by Bioz Stars, 2026-05
    86/100 stars
      Buy from Supplier

    86
    Postnova Analytics af2000 asymmetric flow field flow fractionation af4
    Fig. 1. Schematic showing formation (A) Lipid nanoparticles (LNP) components with difference in ionisable lipids (D-Lin-MC3-DMA referred as MC3 and SM-102), (B) Side-view of frit-inlet <t>AF4</t> channel with protein, LNP and LNP-protein corona in the channel and (C) a representative simulated AF4 profile of Bovine Serum Albumin (BSA) and LNP with the applied cross-flow (XFlow) and detector signal (A) and (B) created with BioRender.com and (C) NovaAnalysis software.
    Af2000 Asymmetric Flow Field Flow Fractionation Af4, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/af2000 asymmetric flow field flow fractionation af4/product/Postnova Analytics
    Average 86 stars, based on 1 article reviews
    af2000 asymmetric flow field flow fractionation af4 - by Bioz Stars, 2026-05
    86/100 stars
      Buy from Supplier

    90
    Postnova Analytics asymmetric flow field flow fractionation (af4, postnova, germany, af2000)
    Fig. 1. Schematic showing formation (A) Lipid nanoparticles (LNP) components with difference in ionisable lipids (D-Lin-MC3-DMA referred as MC3 and SM-102), (B) Side-view of frit-inlet <t>AF4</t> channel with protein, LNP and LNP-protein corona in the channel and (C) a representative simulated AF4 profile of Bovine Serum Albumin (BSA) and LNP with the applied cross-flow (XFlow) and detector signal (A) and (B) created with BioRender.com and (C) NovaAnalysis software.
    Asymmetric Flow Field Flow Fractionation (Af4, Postnova, Germany, Af2000), supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/asymmetric flow field flow fractionation (af4, postnova, germany, af2000)/product/Postnova Analytics
    Average 90 stars, based on 1 article reviews
    asymmetric flow field flow fractionation (af4, postnova, germany, af2000) - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    Postnova Analytics frit-inlet asymmetrical flow-field flow fractionation (fi-af4-uv-mals) af2000 multiflow fff system
    Fig. 1. Schematic showing formation (A) Lipid nanoparticles (LNP) components with difference in ionisable lipids (D-Lin-MC3-DMA referred as MC3 and SM-102), (B) Side-view of frit-inlet <t>AF4</t> channel with protein, LNP and LNP-protein corona in the channel and (C) a representative simulated AF4 profile of Bovine Serum Albumin (BSA) and LNP with the applied cross-flow (XFlow) and detector signal (A) and (B) created with BioRender.com and (C) NovaAnalysis software.
    Frit Inlet Asymmetrical Flow Field Flow Fractionation (Fi Af4 Uv Mals) Af2000 Multiflow Fff System, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/frit-inlet asymmetrical flow-field flow fractionation (fi-af4-uv-mals) af2000 multiflow fff system/product/Postnova Analytics
    Average 90 stars, based on 1 article reviews
    frit-inlet asymmetrical flow-field flow fractionation (fi-af4-uv-mals) af2000 multiflow fff system - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    Postnova Analytics asymmetrical flow field-flow fractionation af4 af2000 focus
    Fig. 1. Schematic showing formation (A) Lipid nanoparticles (LNP) components with difference in ionisable lipids (D-Lin-MC3-DMA referred as MC3 and SM-102), (B) Side-view of frit-inlet <t>AF4</t> channel with protein, LNP and LNP-protein corona in the channel and (C) a representative simulated AF4 profile of Bovine Serum Albumin (BSA) and LNP with the applied cross-flow (XFlow) and detector signal (A) and (B) created with BioRender.com and (C) NovaAnalysis software.
    Asymmetrical Flow Field Flow Fractionation Af4 Af2000 Focus, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/asymmetrical flow field-flow fractionation af4 af2000 focus/product/Postnova Analytics
    Average 90 stars, based on 1 article reviews
    asymmetrical flow field-flow fractionation af4 af2000 focus - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    90
    Postnova Analytics asymmetrical flow field-flow fractionation af4 postnova af2000 focus
    Fig. 1. Schematic showing formation (A) Lipid nanoparticles (LNP) components with difference in ionisable lipids (D-Lin-MC3-DMA referred as MC3 and SM-102), (B) Side-view of frit-inlet <t>AF4</t> channel with protein, LNP and LNP-protein corona in the channel and (C) a representative simulated AF4 profile of Bovine Serum Albumin (BSA) and LNP with the applied cross-flow (XFlow) and detector signal (A) and (B) created with BioRender.com and (C) NovaAnalysis software.
    Asymmetrical Flow Field Flow Fractionation Af4 Postnova Af2000 Focus, supplied by Postnova Analytics, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/result/asymmetrical flow field-flow fractionation af4 postnova af2000 focus/product/Postnova Analytics
    Average 90 stars, based on 1 article reviews
    asymmetrical flow field-flow fractionation af4 postnova af2000 focus - by Bioz Stars, 2026-05
    90/100 stars
      Buy from Supplier

    Image Search Results


    FI-AF4-MD of Poly­(A) LNP formulations. MALS-90° elution profiles with FWHM-integrated radius of gyration and hydrodynamic radii for (A) A-LNPs, (B) B-LNPs, and (C) C-LNPs ( n = 3 ± SD). Cumulative distributions for (D) radius of gyration, (E) hydrodynamic radius, and (F) shape factor ( n = 3), with respective 10, 50, and 90 distributional values for (G) radius of gyration, (H) hydrodynamic radius, and (I) shape factor for A-LNPs, B-LNPs and C-LNPs ( n = 3 ± SD).

    Journal: Molecular Pharmaceutics

    Article Title: The Use of Enhanced Analytical Pipelines for the Characterization of Poly(A) and Poly(A)-LNP Formulation Critical Quality Attributes

    doi: 10.1021/acs.molpharmaceut.5c00614

    Figure Lengend Snippet: FI-AF4-MD of Poly­(A) LNP formulations. MALS-90° elution profiles with FWHM-integrated radius of gyration and hydrodynamic radii for (A) A-LNPs, (B) B-LNPs, and (C) C-LNPs ( n = 3 ± SD). Cumulative distributions for (D) radius of gyration, (E) hydrodynamic radius, and (F) shape factor ( n = 3), with respective 10, 50, and 90 distributional values for (G) radius of gyration, (H) hydrodynamic radius, and (I) shape factor for A-LNPs, B-LNPs and C-LNPs ( n = 3 ± SD).

    Article Snippet: Analytical SEC (aSEC) was performed on the AF2000 Asymmetric-Flow Field-Flow Fractionation (AF4) module (Postnova Analytics, Germany), hyphenated with multiple inline detectors (as per ), using a TOSOH TSKgel UP-SW2000 column (300 × 4.6 mm, 2 μm) and 1× PBS pH 7.4 isocratic mobile phase with a corresponding flow rate of 0.2 mL/min and equivalent injection concentration to that in .

    Techniques:

    Fig. 1. Schematic showing formation (A) Lipid nanoparticles (LNP) components with difference in ionisable lipids (D-Lin-MC3-DMA referred as MC3 and SM-102), (B) Side-view of frit-inlet AF4 channel with protein, LNP and LNP-protein corona in the channel and (C) a representative simulated AF4 profile of Bovine Serum Albumin (BSA) and LNP with the applied cross-flow (XFlow) and detector signal (A) and (B) created with BioRender.com and (C) NovaAnalysis software.

    Journal: Journal of chromatography. A

    Article Title: Frit-inlet asymmetric flow field-flow fractionation for the analysis of lipid nanoparticle-protein interactions.

    doi: 10.1016/j.chroma.2025.465663

    Figure Lengend Snippet: Fig. 1. Schematic showing formation (A) Lipid nanoparticles (LNP) components with difference in ionisable lipids (D-Lin-MC3-DMA referred as MC3 and SM-102), (B) Side-view of frit-inlet AF4 channel with protein, LNP and LNP-protein corona in the channel and (C) a representative simulated AF4 profile of Bovine Serum Albumin (BSA) and LNP with the applied cross-flow (XFlow) and detector signal (A) and (B) created with BioRender.com and (C) NovaAnalysis software.

    Article Snippet: A Postnova Analytics AF2000 asymmetric Flow Field-Flow Fractionation (AF4) (Landsberg, Germany) was used in this study.

    Techniques: Software

    Fig. 2. FI-AF4-UV-MALS fractograms for (A) MC3-LNPs (control) and MC3-LNPs incubated in 35 mg/mL Bovine Serum Albumin (BSA), (B) SM-102 LNPs, (C) MALS fractograms (90◦) plotted for peak 1 and peak 2 for MC3-LNPs incubated in 35 mg/mL BSA, (D) SM-102 LNPs. Time-points indicate 0 hour (control) and 24 h incubation at 37 ◦C. Error bars represent ± S.D mean of triplicate injections. The peaks marked with a red asterisk (*) show enlarged peaks. Vertical dashed lines indicate peak region of interest.

    Journal: Journal of chromatography. A

    Article Title: Frit-inlet asymmetric flow field-flow fractionation for the analysis of lipid nanoparticle-protein interactions.

    doi: 10.1016/j.chroma.2025.465663

    Figure Lengend Snippet: Fig. 2. FI-AF4-UV-MALS fractograms for (A) MC3-LNPs (control) and MC3-LNPs incubated in 35 mg/mL Bovine Serum Albumin (BSA), (B) SM-102 LNPs, (C) MALS fractograms (90◦) plotted for peak 1 and peak 2 for MC3-LNPs incubated in 35 mg/mL BSA, (D) SM-102 LNPs. Time-points indicate 0 hour (control) and 24 h incubation at 37 ◦C. Error bars represent ± S.D mean of triplicate injections. The peaks marked with a red asterisk (*) show enlarged peaks. Vertical dashed lines indicate peak region of interest.

    Article Snippet: A Postnova Analytics AF2000 asymmetric Flow Field-Flow Fractionation (AF4) (Landsberg, Germany) was used in this study.

    Techniques: Control, Incubation